Aixuanda medical equipment Company
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Portable Dual Channel Syringe Medical Vacuum Pumps With CE
Quick Detail:
Automatic infusion Follow the instructions of a doctor or a nurse set the total volume and the rate of an infusion. The pump will accomplish the task automatically.
Description:
1. Four working modes:
Rate mode, Time mode, Weight mode and Drug mode
2. 174 Drugs with 10 Categories of Drug Library
Cardiovascular Sys, Respiratory Sys, Antibiotics Sys, Alimentary Sys.
Nervous Sys, Analgesic Sys, Urinary Sys, Blood Sys, Endocrine Sys.
17 units of dose: Ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, IU/h, U/kg/h, ng/kg/min, can make drug dispensing more convenient and safer.
3. ICU infusion workstation: Combines for syringe pumps and one infusion
Pump with Infusion Support into one ICU Infusion Workstation, sharing a Power Interface.
4. Stackable up to the maximum 8 channels. Transfer the message between the Nurse-call System and the pumps.
5. Bolus Function.
Specifications:
Compatible Syringe: Any standard syringe with 5ml, 10ml, 20ml, 30ml, 50ml and 60ml.
Accuracy: ± 2% (Any manufacturers of syringes, right after calibration)
Delivery rate range:
50 ml syringe - 0.1 1800 ml / hr (0.1 ml / hr step)
30 ml syringe - 0.1 1200 ml / hr (0.1 ml / hr step)
20 ml syringe - 0.1 800 ml / hr (0.1 ml / hr step)
10 ml syringe - 0.1 400 ml / hr (0.1 ml / hr step)
5 ml syringe - 0.1 200 ml / hr (0.1 ml / hr step)
1. Time setting mode range:
Volume: 0.1 999.9ml, 0.1ml step.
Time: 0.1 999.9min, 0.1min step.
2. Drug Library setting mode range:
Sol. Volume: 0.1 199.9ml, 0.1ml step.
Drug mass: 0.1 999.9ml, 0.1 ml step.
Dose: 0.001 9999, 0.001 step.
3. Bolus setting mode range:
Bolus. Volume: 0.1ml 60.0ml, 0.1ml step
Bolus Rate: 5ml: 0.1ml/h 200.0ml/h, 0.1ml/h step
10ml: 0.1ml/h 400.0ml/h, 0.1ml/h step
20ml: 0.1ml/h 800.0ml/h, 0.1ml/h step
30ml: 0.1ml/h 1200.0ml/h, 0.1ml/h step
50ml(60ml): 0.1ml/h 1800.0ml/h, 0.1ml/h step
4. Purge 50ml(60ml): 1800.0ml/h, 20ml(30ml); 800.0ml/h
10ml: 400.0ml/h
5ml: 200.0ml/h
5. KVO rate: 0.1ml/h-1.0ml/h, 0.1ml/h step
6. Alarms: Near empty, Syringe empty, Volume complete (a volume limit has been set), Occlusion, Syringe loss, Syringe dislocated, Operation error, Low battery and other device failures.
7. Power supply: AC 100-240V +/- 10%, 50/60Hz. 10. Power consumption: 25<=VA
8. Internal Lithium Battery: 11.1V, 2000mAh, Approximately 8 hours of continuous operation in a new and fully charged battery running at 5ml/h.
Class: I
9. Safety level: Class I, Type: CF
10. Size: 230mm(L) x 150mm(W) x 125mm(H)
11. Net Weight: 2.2Kg. (Approx)
12. Operating conditions:
Ambient temperature: 5-40° C Relative humidity: 20 to 90%
13. Storage conditions:
Ambient temperature: -10-55° C Relative humidity: 10 to 90%
14. Accessories: AC power line, Operational manual
Competitive Advantage:
Automatic infusion Follow the instructions of a doctor or a nurse set the total volume and the rate of an infusion. The pump will accomplish the task automatically.
Keep Vein Open (KVO) When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Light and Sound Alarm The pump will alarm when infusion line blocked, air bubble in line, pump door open, infusion finished or battery low power. The pump will make a sound and illume corresponding lamps to call the nurse in time.
AC/DC The pump can be powered by external alternate current or build in rechargeable Nickel Metal Hydrogen (NiMH) battery.
Bolus When the pump is stop, bolus function can be used to remove air in line or remove air bubble alarm.
Infusion Rate Setting mode Infusion rate can be set in 2 methods: Drip per minute, milliliter per hour. Users can use either method to set infusion rate.
Self Check when Power on When power on, the pump will make a self test to test if all parts were in order, all lamps are lighted. If any part is not in order, the corresponding lamp will turn off.
Volume accumulate display and zero The pump can accumulate infusion volume, and the user can reset the volume display to zero.